NIR Relative Photometric Calibration factors between detectors

Data product name

RelPhotoDetCalibration

Data product custodian

NIR

Data model tag

R-1.6.7

Name of the Schema file

euc-test-nir-RelPhotoDetCalibration.xsd

Schema documentation tag

Documentation for data product element DpdNirRelPhotoDetCalibration:

Data Product containing relative photometric calibration parameters between different detectors.

Data product elements

Header of type: sys:genericHeader

Data of type: nir:nirRelPhotoDetCal

Parameters of type: ppr:genericKeyValueParameters

Processing Element(s) creating/using the data product

It is created by a dedicated calibration pipeline using monthly observations of the self-calibration field.

It is used by the NIR_RelativePhotometry PE.

Processing function using the data product

This is an internal NIR data product, and it is used only by the NIR PF and the dedicated NIR calibration pipeline.

Detailed description of the data product

This is a XML file containing a list of correction factors with associated errors and units for each detector, as well as specific information on the calibration procedure, i.e. calibration version, temporal validity range, and filter.