NIR Relative Photometric Calibration factors between detectors¶
Data product name¶
RelPhotoDetCalibration
Data product custodian¶
NIR
Data model tag¶
R-1.6.7
Name of the Schema file¶
euc-test-nir-RelPhotoDetCalibration.xsd
Schema documentation tag¶
Documentation for data product element DpdNirRelPhotoDetCalibration:
Data Product containing relative photometric calibration parameters between different detectors.
Data product elements¶
Header of type: sys:genericHeader
Data of type: nir:nirRelPhotoDetCal
Parameters of type: ppr:genericKeyValueParameters
Processing Element(s) creating/using the data product¶
It is created by a dedicated calibration pipeline using monthly observations of the self-calibration field.
It is used by the NIR_RelativePhotometry PE.
Processing function using the data product¶
This is an internal NIR data product, and it is used only by the NIR PF and the dedicated NIR calibration pipeline.
Detailed description of the data product¶
This is a XML file containing a list of correction factors with associated errors and units for each detector, as well as specific information on the calibration procedure, i.e. calibration version, temporal validity range, and filter.